BS 8215, BS 8102 and BS 5250 — the damp-proofing standards

Approved Document C sets out the numbers. It also names three standards as an alternative route to meeting the same requirement — and they cover the cases the diagrams do not.

Three standards, three different problems

The words "damp" and "damp-proofing" cover at least three distinct problems, and Approved Document C names a different standard for each:

The damp standards and what each covers, as described in Approved Document C (2013 edition)
StandardTitle as cited in the approved documentThe problem it addresses
BS 8215:1991Code of practice for design and installation of damp-proof courses in masonry constructionDamp-proof courses in walls — the 150 mm height and 225 mm cavity rules sit in a detail code that also covers installation.
BS 8102:1990Code of practice for protection of structures against water from the groundWater arriving from the ground under pressure — basements and below-ground structures, which the standard diagrams do not cover.
BS 5250:2002Code of practice for the control of condensation in buildingsCondensation — vapour moving through the construction and condensing where it should not.
BS EN ISO 13788:2002Hygrothermal performance of building components and building elements (cited alongside BS 5250)The method used to assess the risk of interstitial condensation.

How the approved document uses them

Part C does not present these standards as optional background. Its structure is a technical solution followed by an alternative approach, and the standards are the alternative route:

Why the distinction matters on a real job

Choosing the wrong one wastes money in a way that is hard to see.

The numbers themselves — a damp-proof course at least 150 mm above adjoining ground, a cavity taken down at least 225 mm below the lowest damp-proof course with weep holes every 900 mm — are set out on our Approved Document C page with their paragraph references.

A note on editions

The editions in the table above are the ones cited by Approved Document C — that is the citation the regulation rests on, and it is why they are the editions named there. Three of them are still current exactly as cited: BS 8215:1991, BS 8104:1992 and CP 102:1973. The rest have moved on. The current editions, read from the BSI catalogue on 22 September 2026, are BS 8102:2022 (title now Protection of below ground structures against water ingress), BS 5250:2021 (title now Management of moisture in buildings) and BS EN ISO 13788:2012. Cite the current edition when you specify; cite the approved document when you are explaining why the rule exists.

Edition status — what the approved document cites, and what is current

An approved document names the edition of a standard that existed when it was written. That edition is not necessarily the current one. The table below sets out, for every standard this page relies on, the title as published, the edition the approved document cites, and the edition BSI catalogues today (22 September 2026). Where the cited edition is withdrawn, the page says so; where we could not confirm the replacement, no current edition is stated.

Standard → title as published by BSI → the edition cited by the approved document → the current edition (BSI catalogue, checked 22 September 2026)
StandardTitle as publishedEdition cited by the approved documentCurrent edition (BSI)
BS 8215Code of practice for design and installation of damp-proof courses in masonry constructionBS 8215:1991 — cited by Approved Document CBS 8215:1991 — Current (28 February 1991)
BS 8102Protection of below ground structures against water ingress. Code of practiceBS 8102:1990 — cited by Approved Document C as "Code of practice for protection of structures against water from the ground"BS 8102:2022 — Current (31 March 2022). Note the title has changed as well as the edition
BS 5250Management of moisture in buildings. Code of practiceBS 5250:2002 — cited by Approved Document C as "Code of practice for the control of condensation in buildings"BS 5250:2021 — Current
BS EN ISO 13788Hygrothermal performance of building components and building elements — Internal surface temperature to avoid critical surface humidity and interstitial condensation. Calculation methodsBS EN ISO 13788:2002 — cited by Approved Document CBS EN ISO 13788:2012 — Current
BS 8104Code of practice for assessing exposure of walls to wind-driven rainBS 8104:1992 — cited by Approved Document CBS 8104:1992 — Current, Under Review
BS CP 102Code of practice for protection of buildings against water from the groundBS CP 102:1973 — cited by Approved Document CCP 102:1973 — Current (catalogued without the BS prefix)

Source: BSI catalogue records read at knowledge.bsigroup.com on 22 September 2026. Each title, designation, status and date in the last two columns was read from the BSI catalogue page for that standard.

Last verified 22 September 2026. Every requirement quoted on this page was read from the primary source listed below on that date, not from a summary. If a figure could not be confirmed in the primary source it is not on this page.

Where these figures come from

Guidance only, not advice

This page is a plain-English summary of published regulations and standards, written to help you plan a job. It is not professional advice, it is not a substitute for the actual document, and it is not a building-control decision.

Building regulations are enforced by your local authority (or an approved inspector) and the facts of a particular job can change the answer. Confirm with your local building control before you start work, and where a job is structural, get it designed by a suitably qualified person. If this page and the source document disagree, the source document wins.